Ground leakage current reduction in single-phase current source inverter topologies
Contributo in Atti di convegno
Data di Pubblicazione:
2016
Citazione:
Ground leakage current reduction in single-phase current source inverter topologies / Migliazza, Giovanni; Lorenzani, Emilio; Immovilli, Fabio; Bianchini, Claudio. - (2016), pp. 2325-2330. ( 42nd Conference of the Industrial Electronics Society, IECON 2016 Palazzo dei Congressi, ita 2016) [10.1109/IECON.2016.7793966].
Abstract:
This paper presents a grid-tied single phase photovoltaic microinverter based on Current Source Inverter (CSI) topology. The main topic of this work is related to the identification of a topology and a PWM strategy able to minimize the obvious issues of the basic CSI solution: efficiency and ground leakage current. The strong reduction of this last issue allows the use of the proposed solution in conjunction with Photovoltaic module in building integrated installations. Simulation results and a low voltage experimental validation present the effectiveness of the proposed solution in mitigating ground leakage currents.
Tipologia CRIS:
Relazione in Atti di Convegno
Keywords:
Current Source Inverter; Grid-connected Converters; Ground Leakge Current; Photovoltaic Systems; Single Phase Systems; Control and Systems Engineering; Electrical and Electronic Engineering
Elenco autori:
Migliazza, Giovanni; Lorenzani, Emilio; Immovilli, Fabio; Bianchini, Claudio
Link alla scheda completa:
Titolo del libro:
IECON Proceedings (Industrial Electronics Conference)
Pubblicato in: