Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Cardiac resynchronization therapy: Implant rates, temporal trends and relationships with heart failure epidemiology

Articolo
Data di Pubblicazione:
2014
Citazione:
Cardiac resynchronization therapy: Implant rates, temporal trends and relationships with heart failure epidemiology / Boriani, Giuseppe; Berti, Elena; Belotti, Laura Maria Beatrice; Biffi, Mauro; Carboni, Angelo; Bandini, Alberto; Casali, Edoardo; Tomasi, Corrado; Toselli, Tiziano; Baraldi, Paolo; Bottoni, Nicola; Barbato, Gaetano; Sassone, Biagio. - In: JOURNAL OF CARDIOVASCULAR MEDICINE. - ISSN 1558-2027. - 15:2(2014), pp. 147-154. [10.2459/JCM.0b013e3283638d90]
Abstract:
BACKGROUND: Consensus guidelines define indications for cardiac resynchronization therapy (CRT), but the variability in implant rates in 'real world' clinical practice, as well as the relationship with the epidemiology of heart failure are not defined. METHODS AND RESULTS: In Emilia-Romagna, an Italian region with around 4.4 million inhabitants, a registry was instituted to collect data on implanted devices for CRT, with (CRT-D) or without defibrillation (CRT-P) capabilities. Data from all consecutive patients resident in this region who underwent a first implant of a CRT device in years 2006-2010 were collected and standardized (considering each of the nine provinces of the region). The number of CRT implants increased progressively, with a 71% increase in 2010 compared to 2006. Between 84 and 90% of implants were with CRT-D devices. The variability in standardized implant rates among the provinces was substantial and the ratio between the provinces with the highest and the lowest implant rates was always greater than 2. Considering prevalent cases of heart failure in the period 2006-2010, the proportion of patients implanted with CRT per year ranged between 0.23 and 0.30%. CONCLUSIONS: The application in 'real world' clinical practice of CRT in heart failure is quite heterogeneous, with substantial variability even among areas belonging to the same region, with the need to make the access to this treatment more equitable. Despite the increased use of CRT, its overall rate of adoption is low, if a population of prevalent heart failure patients is selected on the basis of administrative data on hospitalizations. © 2014 Italian Federation of Cardiology.
Tipologia CRIS:
Articolo su rivista
Keywords:
cardiac resynchronization therapy; defibrillators; epidemiology; heart failure; hospitalizations; Aged; Cardiac Resynchronization Therapy; Cardiac Resynchronization Therapy Devices; Defibrillators, Implantable; Electric Countershock; Female; Health Services Accessibility; Healthcare Disparities; Heart Failure; Hospitalization; Humans; Italy; Male; Practice Patterns, Physicians'; Prevalence; Prospective Studies; Prosthesis Design; Registries; Time Factors; Treatment Outcome; Cardiology and Cardiovascular Medicine
Elenco autori:
Boriani, Giuseppe; Berti, Elena; Belotti, Laura Maria Beatrice; Biffi, Mauro; Carboni, Angelo; Bandini, Alberto; Casali, Edoardo; Tomasi, Corrado; Toselli, Tiziano; Baraldi, Paolo; Bottoni, Nicola; Barbato, Gaetano; Sassone, Biagio
Autori di Ateneo:
BORIANI Giuseppe
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1139701
Pubblicato in:
JOURNAL OF CARDIOVASCULAR MEDICINE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0