Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Can smartphone sleep applications reliably assess sleep-wake cycle? Preliminary findings from a PSG study

Abstract
Data di Pubblicazione:
2018
Citazione:
Can smartphone sleep applications reliably assess sleep-wake cycle? Preliminary findings from a PSG study / Mazzetti, M; Fino, E; Pizza, F; Vandi, S; Plazzi, G.. - In: JOURNAL OF SLEEP RESEARCH. - ISSN 0962-1105. - 27:(2018), pp. 657-657. ( 24th Congress of the European-Sleep-Research-Society (ESRS) Basel, SWITZERLAND SEP 25-28, 2018) [10.1111/jsr.12750].
Abstract:
Objectives: Smartphone applications are considered as the prime candidate for the purposes of large scale, low cost and long term sleep monitoring. How reliable is smartphone assessment of sleep remains a key issue and more validation studies with both healthy and patient populations are needed. In this study we compared the performance of four smartphone applications (Sleep Cycle-accelerometer; Sleep Cycle-microphone; Smart Alarm; Sense) with polysomnoghraphy (PSG). Our main objective was evaluating whether sleep reports provided by applications offer reliable assessment of standard sleep parameters and establishing which of the application features result more promising for personal home use. Methods: 20 healthy participants were recorded at home, for two consecutive nights. Four iPhone applications (two per each night) designed for sleep–wake detection were used simultaneously with PSG. Results: Pearson’s correlation coefficients between PSG parameters (Time in bed, TIB; Total Sleep Time, TST; Wake After Sleep Onset, WASO; Sleep Efficiency, SE; Sleep Latency, SL; NREM Sleep Stages 1-4, N1, N2, N3, N4; Slow Wave Sleep, SWS; Rapid Eye Movement Sleep, REMS) and app reports were calculated. Significant correlations are reported below. Sense: TIB (app) and TIB (PSG): r= .713, p=.003; TST (app) and TST (PSG): r= .777, p=.001; Sleep Score (app) and SE (PSG): r= .482, p=.069; Light Sleep (app) and N1+N2+ REM (PSG): r= .424, p=.062; Sleeping Soundly(app) and N3: r= .596, p=.019; Sleeping Soundly(app) and N4(PSG): r= .520, p=.047. Smart Alarm: TIB (app) and TIB (PSG): r= .944, p< .001; Time Awake (app) and WASO (PSG): r= .473, p=.035; Sleep Quality (app) and SE(PSG): r= .431, p=.057. Sleep Cycle-accelerometer: TIB(app) and TIB (PSG): r= .672, p=.002; Sleep quality (app) and SE (PSG): r= -.480, p=.038. Sleep Cycle-microphone: TIB (app) and TIB (PSG): r= .492, p=.045; Sleep quality (app) and TIB (PSG): r= -.522, p=.032. Conclusions: Two apps provided partially reliable estimates of SE and showed significant correlations with TST and WASO measured by PSG. Only one app showed significant correlations with SWS parameters. In general, the examined apps do not offer reliable sleep stage data, not discriminating light sleep from deep sleep and especially not providing any estimate of REM.
Tipologia CRIS:
Abstract in Atti di Convegno
Keywords:
Smartphone sleep applications; Polysomnography; Sleep-Wake Cycle; Sleep Staging.
Elenco autori:
Mazzetti, M; Fino, E; Pizza, F; Vandi, S; Plazzi, G.
Autori di Ateneo:
PLAZZI Giuseppe
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1205742
Titolo del libro:
JOURNAL OF SLEEP RESEARCH
Pubblicato in:
JOURNAL OF SLEEP RESEARCH
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0