Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

A novel spleen-dedicated stiffness measurement by FibroScan® improves the screening of high-risk oesophageal varices

Articolo
Data di Pubblicazione:
2020
Citazione:
A novel spleen-dedicated stiffness measurement by FibroScan® improves the screening of high-risk oesophageal varices / Stefanescu, H., Marasco, G., Cales, P., Fraquelli, M., Rosselli, M., Ganne-Carrie, N., De Ledinghen, V., Ravaioli, F., Colecchia, A., Rusu, C., Andreone, P., Mazzella, G., Festi, D.. - In: LIVER INTERNATIONAL. - ISSN 1478-3223. - 40:1(2020), pp. 175-185. [10.1111/liv.14228]
Abstract:
Background & Aims Several non-invasive tests (NITs) have been developed to diagnose oesophageal varices (EV), including the recent Baveno VI criteria to rule out high-risk varices (HRV). Spleen stiffness measurement (SSM) with the standard FibroScan (R) (SSM@50Hz) has been evaluated. However, the EV grading could be underestimated because of a ceiling threshold (75 kPa) of the SSM@50Hz. The aims were to evaluate SSM by a novel spleen-dedicated FibroScan (R) (SSM@100Hz) for EV diagnosis compared with SSM@50Hz, other validated NITs and Baveno VI criteria. Methods This prospective multicentre study consecutively enrolled patients with chronic liver disease; blood data, endoscopy, liver stiffness measurement (LSM), SSM@50Hz and SSM@100Hz were collected. Results Two hundred and sixty patients met inclusion criteria. SSM@100Hz success rate was significantly higher than that of SSM@50Hz (92.5% vs 76.0%, P < .001). SSM@100Hz accuracy for the presence of EV (AUC = 0.728) and HRV (AUC = 0.756) was higher than in other NITs. SSM@100Hz AUC for large EV (0.782) was higher than SSM@50Hz (0.720, P = .027). AUC for HRV with SSM@100Hz (0.780) was higher than with LSM (0.615, P < .001). The spared endoscopy rate of Baveno VI criteria (8.1%) was significantly increased by the combination to SSM@50Hz (26.5%) or SSM@100Hz (38.9%, P < .001 vs others). The missed HRV rate was, respectively, 0% and 4.7% for combinations. Conclusions SSM@100Hz is a new performant non-invasive marker for EV and HRV providing a higher accuracy than SSM@50Hz and other NITs. The combination of Baveno VI criteria and SSM@100Hz significantly increased the spared endoscopy rate compared to Baveno VI criteria alone or combined with SSM@50Hz. Clinical trial number: NCT02180113.
Tipologia CRIS:
Articolo su rivista
Keywords:
Baveno VI criteria; liver stiffness measurement; portal hypertension; spleen stiffness measurement
Elenco autori:
Stefanescu, H.; Marasco, G.; Cales, P.; Fraquelli, M.; Rosselli, M.; Ganne-Carrie, N.; De Ledinghen, V.; Ravaioli, F.; Colecchia, A.; Rusu, C.; Andreone, P.; Mazzella, G.; Festi, D.
Autori di Ateneo:
Colecchia Antonio
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1237350
Pubblicato in:
LIVER INTERNATIONAL
Journal
  • Dati Generali

Dati Generali

URL

http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1478-3231
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.2.0