Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Echocardiographic Left Ventricular Mass Assessment: Correlation between 2D-Derived Linear Dimensions and 3-Dimensional Automated, Machine Learning-Based Methods in Unselected Patients

Articolo
Data di Pubblicazione:
2021
Citazione:
Echocardiographic Left Ventricular Mass Assessment: Correlation between 2D-Derived Linear Dimensions and 3-Dimensional Automated, Machine Learning-Based Methods in Unselected Patients / Barbieri, Andrea; Bursi, Francesca; Camaioni, Giovanni; Maisano, Anna; Imberti, Jacopo Francesco; Albini, Alessandro; De Mitri, Gerardo; Mantovani, Francesca; Boriani, Giuseppe. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 10:6(2021), pp. 1-10. [10.3390/jcm10061279]
Abstract:
A recently developed algorithm for 3D analysis based on machine learning (ML) principles detects left ventricular (LV) mass without any human interaction. We retrospectively studied the correlation between 2D-derived linear dimensions using the ASE/EACVI-recommended formula and 3D automated, ML-based methods (Philips HeartModel) regarding LV mass quantification in unselected patients undergoing echocardiography. We included 130 patients (mean age 60 +/- 18 years; 45% women). There was only discrete agreement between 2D and 3D measurements of LV mass (r = 0.662, r(2) = 0.348, p < 0.001). The automated algorithm yielded an overestimation of LV mass compared to the linear method (Bland-Altman positive bias of 13.1 g with 95% limits of the agreement at 4.5 to 21.6 g, p = 0.003, ICC 0.78 (95%CI 0.68-8.4). There was a significant proportional bias (Beta -0.22, t = -2.9) p = 0.005, the variance of the difference varied across the range of LV mass. When the published cut-offs for LV mass abnormality were used, the observed proportion of overall agreement was 77% (kappa = 0.32, p < 0.001). In consecutive patients undergoing echocardiography for any indications, LV mass assessment by 3D analysis using a novel ML-based algorithm showed systematic differences and wide limits of agreements compared with quantification by ASE/EACVI- recommended formula when the current cut-offs and partition values were applied.
Tipologia CRIS:
Articolo su rivista
Keywords:
2D echocardiography; 3D echocardiography; left ventricular mass; machine learning
Elenco autori:
Barbieri, Andrea; Bursi, Francesca; Camaioni, Giovanni; Maisano, Anna; Imberti, Jacopo Francesco; Albini, Alessandro; De Mitri, Gerardo; Mantovani, Francesca; Boriani, Giuseppe
Autori di Ateneo:
BORIANI Giuseppe
Imberti Jacopo Francesco
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1251500
Link al Full Text:
https://iris.unimore.it//retrieve/handle/11380/1251500/482226/jcm-10-01279.pdf
Pubblicato in:
JOURNAL OF CLINICAL MEDICINE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0