Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Incidence and Predictors of Infections and All-Cause Death in Patients with Cardiac Implantable Electronic Devices: The Italian Nationwide RI-AIAC Registry

Articolo
Data di Pubblicazione:
2022
Citazione:
Incidence and Predictors of Infections and All-Cause Death in Patients with Cardiac Implantable Electronic Devices: The Italian Nationwide RI-AIAC Registry / Boriani, G.; Proietti, M.; Bertini, M.; Diemberger, I.; Palmisano, P.; Baccarini, S.; Biscione, F.; Bottoni, N.; Ciccaglioni, A.; Monte, A. D.; Ferrari, F. A.; Iacopino, S.; Piacenti, M.; Porcelli, D.; Sangiorgio, S.; Santini, L.; Malagu, M.; Stabile, G.; Imberti, J. F.; Caruso, D.; Zoni-Berisso, M.; De Ponti, R.; Ricci, R. P.. - In: JOURNAL OF PERSONALIZED MEDICINE. - ISSN 2075-4426. - 12:1(2022), pp. 1-16. [10.3390/jpm12010091]
Abstract:
Background: The incidence of infections associated with cardiac implantable electronic devices (CIEDs) and patient outcomes are not fully known. Aim: To provide a contemporary assessment of the risk of CIEDs infection and associated clinical outcomes. Methods: In Italy, 18 centres enrolled all consecutive patients undergoing a CIED procedure and entered a 12-months follow-up. CIED infections, as well as a composite clinical event of infection or all-cause death were recorded. Results: A total of 2675 patients (64.3% male, age 78 (70–84)) were enrolled. During follow up 28 (1.1%) CIED infections and 132 (5%) deaths, with 152 (5.7%) composite clinical events were observed. At a multivariate analysis, the type of procedure (revision/upgrading/reimplantation) (OR: 4.08, 95% CI: 1.38–12.08) and diabetes (OR: 2.22, 95% CI: 1.02–4.84) were found as main clinical factors associated to CIED infection. Both the PADIT score and the RI-AIAC Infection score were significantly associated with CIED infections, with the RI-AIAC infection score showing the strongest association (OR: 2.38, 95% CI: 1.60–3.55 for each point), with a c-index = 0.64 (0.52–0.75), p = 0.015. Regarding the occurrence of composite clinical events, the Kolek score, the Shariff score and the RI-AIAC Event score all predicted the outcome, with an AUC for the RI-AIAC Event score equal to 0.67 (0.63−0.71) p < 0.001. Conclusions: In this Italian nationwide cohort of patients, while the incidence of CIED infections was substantially low, the rate of the composite clinical outcome of infection or all-cause death was quite high and associated with several clinical factors depicting a more impaired clinical status.
Tipologia CRIS:
Articolo su rivista
Keywords:
Cardiac implantable electronic device; Implantable defibrillator; Infection; Outcome; Pacemaker
Elenco autori:
Boriani, G.; Proietti, M.; Bertini, M.; Diemberger, I.; Palmisano, P.; Baccarini, S.; Biscione, F.; Bottoni, N.; Ciccaglioni, A.; Monte, A. D.; Ferrari, F. A.; Iacopino, S.; Piacenti, M.; Porcelli, D.; Sangiorgio, S.; Santini, L.; Malagu, M.; Stabile, G.; Imberti, J. F.; Caruso, D.; Zoni-Berisso, M.; De Ponti, R.; Ricci, R. P.
Autori di Ateneo:
BORIANI Giuseppe
Imberti Jacopo Francesco
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1279246
Link al Full Text:
https://iris.unimore.it//retrieve/handle/11380/1279246/474182/jpm-12-00091.pdf
Pubblicato in:
JOURNAL OF PERSONALIZED MEDICINE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0