Comparison of point-shear wave elastography (ElastPQ) and transient elastography (FibroScan) for liver fibrosis staging in patients with non-alcoholic fatty liver disease
Articolo
Data di Pubblicazione:
2022
Citazione:
Comparison of point-shear wave elastography (ElastPQ) and transient elastography (FibroScan) for liver fibrosis staging in patients with non-alcoholic fatty liver disease / Roccarina, D., Iogna Prat, L., Pallini, G., Guerrero Misas, M., Buzzetti, E., Saffioti, F., Arico, F.M., Mantovani, A., Koutli, E., Goyale, A., Rosselli, M., Luong, T.V., Pinzani, M., Tsochatzis, E.A.. - In: LIVER INTERNATIONAL. - ISSN 1478-3223. - 42:10(2022), pp. 2195-2203. [10.1111/liv.15297]
Abstract:
Background and Aims: ElastPQ is a point shear wave elastography technique used to non-invasively assess liver fibrosis. We compared liver stiffness measurements (LSM) by ElastPQ and fibroscan transient elastography (F-TE) in a cohort of patients with non-alcoholic fatty liver disease (NAFLD). We further evaluated the performance of ElastPQ in a subgroup of patients with available liver histology. Materials and Methods: We included patients with NAFLD who presented in a dedicated multidisciplinary clinic. Anthropometric parameters, blood tests and elastography measurements were obtained using F-TE and ElastPQ as part of routine clinical care. Results: We enrolled 671 patients with NAFLD, mean age 55.8 ± 13 years, body mass index (BMI) 31.5 ± 5.7 kg/m2, 56.6% males, 41% diabetes, 53.7% hypertension, 68% dyslipidaemia. ElastPQ showed an excellent correlation with F-TE (Spearman's r = 0.80, p <.001), which was better for mild/moderate stages of fibrosis. Independent predictors of a >2 kPa discrepancy between the two techniques were a larger waist circumference and F-TE ≥10 kPa. In the subgroup of 159 patients with available histology, ElastPQ showed similar diagnostic accuracy with F-TE in staging liver fibrosis (ElastPQ area under the curves 0.84, 0.83, 0.86 and 0.95, for F ≥ 1, F ≥ 2, F ≥ 3 and F = 4 respectively). Optimal cut-off values of ElastPQ for individual fibrosis stages were lower than those of F-TE. Conclusions: ElastPQ shows an excellent correlation with F-TE in patients with NAFLD, which was better for lower LSM. The optimal cut-off values of ElastPQ are lower than those of F-TE for individual stages of fibrosis. ElastPQ has similar diagnostic accuracy to F-TE for all stages of fibrosis.
Tipologia CRIS:
Articolo su rivista
Keywords:
acoustic radiation force impulse; Elast-PQ point-shear wave elastography; liver elastography; liver fibrosis; non-alcoholic fatty liver disease; transient elastography; Adult; Aged; Female; Fibrosis; Humans; Liver; Liver Cirrhosis; Male; Middle Aged; Elasticity Imaging Techniques; Non-alcoholic Fatty Liver Disease
Elenco autori:
Roccarina, D.; Iogna Prat, L.; Pallini, G.; Guerrero Misas, M.; Buzzetti, E.; Saffioti, F.; Arico, F. M.; Mantovani, A.; Koutli, E.; Goyale, A.; Rosselli, M.; Luong, T. V.; Pinzani, M.; Tsochatzis, E. A.
Link alla scheda completa:
Pubblicato in: