Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Influence of NiTi wire diameter on cyclic and torsional fatigue resistance of different heat-treated endodontic instruments

Articolo
Data di Pubblicazione:
2022
Citazione:
Influence of NiTi wire diameter on cyclic and torsional fatigue resistance of different heat-treated endodontic instruments / Pedullà, E; Canova, Fs; La Rosa, Grm; Naaman, A; Diemer, F; Generali, L; Nehme, W. - In: MATERIALS. - ISSN 1996-1944. - 15:19(2022), pp. 1-9. [10.3390/ma15196568]
Abstract:
We compared the mechanical properties of 2Shape mini TS2 (Micro-Mega, Besançon, France) obtained from 1.0 diameter nickel-titanium (NiTi) wires and 2Shape TS2 from 1.2 diameter nickel-titanium (NiTi) wires differently thermally treated at room and body temperature. We used 120 NiTi TS2 1.0 and TS2 1.2 files made from controlled memory (CM) wire and T-wire (n = 10). Cyclic fatigue resistance was tested by recording the number of cycles to fracture (NCF) at room and body temperatures using a customized testing device. Maximum torque and angle of rotation at failure were recorded, according to ISO 3630-1. Data were analyzed by a two-way ANOVA (p < 0.05). The CM-wire files had significantly higher NCFs at both temperatures, independent of wire dimensions. Testing at body temperature negatively affected cyclic fatigue of all files. The 1.0-mm diameter T-wire instruments showed higher NCF than the 1.2-mm diameter, whereas no significant differences emerged between the two CM wires at either temperature. The maximum torque was not significantly different across files. The TS2 CM-wire files showed significantly higher angular rotation to fracture than T-wire files. The TS2 CM-wire prototypes showed higher cyclic fatigue resistance than T-wire prototypes, regardless of wire size, exhibiting suitable torsional properties. Torsional behavior appears to not be affected by NiTi wire size.
Tipologia CRIS:
Articolo su rivista
Keywords:
cyclic fatigue; endodontics; heat treatment; NiTi wire diameter; torsional fatigue; 2Shape
Elenco autori:
Pedullà, E; Canova, Fs; La Rosa, Grm; Naaman, A; Diemer, F; Generali, L; Nehme, W
Autori di Ateneo:
GENERALI Luigi
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1289825
Link al Full Text:
https://iris.unimore.it//retrieve/handle/11380/1289825/450737/Influence%20of%20NiTi%20wire%20diameter%20on%20cyclic%20and%20torsional%20fatigue%20resistance%20of%20different%20heat-treated%20endodontic%20instruments.pdf
Pubblicato in:
MATERIALS
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.2.0.2