Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Accuracy of funduscopy to identify true edema versus pseudoedema of the optic disc

Articolo
Data di Pubblicazione:
2012
Citazione:
Accuracy of funduscopy to identify true edema versus pseudoedema of the optic disc / A., Carta; Favilla, Stefania; Prato, Marco; S., Bianchi Marzoli; A. A., Sadun; P., Mora. - In: INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE. - ISSN 0146-0404. - STAMPA. - 53:1(2012), pp. 1-6. [10.1167/iovs.11-8082]
Abstract:
Purpose: Differential diagnosis between true optic disc edema(ODE) and optic disc pseudo-edema (PODE) remains a clinicalchallenge even for experienced neuro-ophthalmologists. The aim of the study was to assess the accuracy, sensitivity, and specificity of the funduscopic diagnosis of ODE.Methods: Observational, cross-sectional, two-center study ofsubjects referred for presumed acute ODE. Fundoscopy wasconducted in each center by two blinded neuro-ophthalmologistswho completed a forced-choice form concerning thepresence/absence of the ten clinical signs of ODE. Data from 122patients were used for modeling analysis. There were 74 patients in the ODE group and 48 patients in the PODE group. Main outcome measures were accuracy, sensitivity, and specificity in identifying true ODE from all possible combinations of ophthalmoscopic signs, provided by Support Vector Machine (SVM) analysis.Results: To identify ODE the sign SWELLING (i.e., swelling of theperipapillary retinal nerve fiber layer) had the highest accuracy(0.92; 95% CI: 0.82–0.97). All three outcomes showed littlevariation when the combination consisted of more than four signs.The best four-sign combination was: SWELLING, HEMORRHAGES,papilla ELEVATION, and CONGESTION of peripapillary vessels(accuracy = 0.93, 95% CI: 0.83–0.98; sensitivity = 0.95; andspecificity = 0.89).Conclusions: In our series of presumed ODE, 48/122 (39%) caseswere finally diagnosed as PODE. The sign SWELLING had thehighest accuracy as a single sign, and was a component of the most accurate combinations of signs. Accuracy reached a high plateau level if at least 4 (out of 10) ophthalmoscopic signs were present.
Tipologia CRIS:
Articolo su rivista
Keywords:
optic disc; optic nerve head; statistics
Elenco autori:
A., Carta; Favilla, Stefania; Prato, Marco; S., Bianchi Marzoli; A. A., Sadun; P., Mora
Autori di Ateneo:
PRATO Marco
Link alla scheda completa:
https://iris.unimore.it/handle/11380/684352
Pubblicato in:
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.4.4.0