Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Simultaneous correction of post-traumatic aphakia and aniridia with the use of artificial iris and IOL implantation

Articolo
Data di Pubblicazione:
2013
Citazione:
Simultaneous correction of post-traumatic aphakia and aniridia with the use of artificial iris and IOL implantation / Forlini, C., Forlini, M., Rejdak, R., Prokopiuk, A., Levkina, O., Bratu, A., Rossini, P., Cagampang, P.R., Cavallini, G.M.. - In: GRAEFE'S ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY. - ISSN 0721-832X. - STAMPA. - 251:3(2013), pp. 667-675. [10.1007/s00417-012-2254-7]
Abstract:
Abstract
BACKGROUND:
Combined post-traumatic aniridia and aphakia demand extensive and complex reconstructive surgery. We present our approach for simultaneous correction of this surgical situation with the use of the ArtificialIris (Dr. Schmidt Intraocularlinsen GmbH, Germany) with a foldable acrylic IOL Lentis L-313 (Oculentis, GmbH, Germany) sutured to its surface. The novelty (our first operation was on June 2010) of this surgical technique is based on the combined use of foldable (with closed haptics) IOL and Artificialiris to correct post-traumatic aniridia and aphakia.

METHODS:
Four consecutive cases of combined post-traumatic lesions of iris and lens, corrected with complex device ArtificialIris and foldable IOL. In two cases, the compound implant was sutured to the sclera in sulcus during the penetrating keratoplasty; in another case, it was positioned through a corneal incision of about 5.0 mm with transscleral fixation, and in one patient with preserved capsular support and possibility of IOL in-the-bag implantation the ArtificialIris was placed in sulcus sutureless through a clear corneal tunnel.

RESULTS:
Maximal follow-up was 6 months. The complex device was placed firmly fixed within the sulcus, including in the eye implanted without sutures, and showed a stable and centered position without any tilt or torque.

CONCLUSION:
Management of post-traumatic aniridia combined with aphakia by haptic fixation of a foldable acrylic IOL on a foldable iris prosthesis appears to be a promising approach which gives the surgeon the possibility to correct a complex lesion with one procedure, which is less traumatic and faster. Existence of foldable materials, both iris and IOL, permits relatively small corneal incisions (4.0-5.0 mm). Moreover, the custom-tailored iris prosthesis gives a perfect aesthetic result.
Tipologia CRIS:
Articolo su rivista
Keywords:
Adolescent; Aniridia; Aphakia; Cataract Extraction; Corneal Injuries; Endotamponade; Eye Injuries, Penetrating; Humans; Keratoplasty, Penetrating; Middle Aged; Silicone Oils; Vitrectomy; Artificial Organs; Iris; Lens Implantation, Intraocular
Elenco autori:
Forlini, Cesare; Forlini, Matteo; Rejdak, Robert; Prokopiuk, Agata; Levkina, Oxana; Bratu, Adriana; Rossini, Paolo; Cagampang, Perfecto R; Cavallini, Gian Maria
Autori di Ateneo:
CAVALLINI Gian Maria
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1061761
Pubblicato in:
GRAEFE'S ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.2.0