Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills
  1. Research Outputs

Structural analysis of HyFlex EDM instruments

Academic Article
Publication Date:
2017
Short description:
Structural analysis of HyFlex EDM instruments / Iacono, F., Pirani, C., Generali, L., Bolelli, G., Sassatelli, P., Lusvarghi, L., Gandolfi, M.G., Giorgini, L., Prati, C.. - In: INTERNATIONAL ENDODONTIC JOURNAL. - ISSN 0143-2885. - STAMPA. - 50:3(2017), pp. 303-313. [10.1111/iej.12620]
abstract:
Aim To compare the phase transformation behaviour, the microstructure, the nano-hardness and the surface chemistry of electro-discharge machined HyFlex EDM instruments with conventionally manufactured HyFlex CM.
Methodology New and laboratory used HyFlex EDM were examined by X-ray diffraction (XRD) and differential scanning calorimetry (DSC). Nano-hard- ness and modulus of elasticity were also investigated using a maximum load of 20 mN with a minimum of 40 significant indentations for each sample. Raman spectroscopy and field emission-scanning electron microscope (FE-SEM) were used to assess the surface chemistry of HyFlex EDM. HyFlex CM were subjected to the same investigations and used as a comparison. Nano-indentation data were statistically analysed using the Student’s t-test.Results XRD analysis on HyFlex EDM revealed the presence of martensite and rhombohedral R-phase, while a mixture of martensite and austenite structure was identified in HyFlex CM. DSC analysis also dis- closed higher austenite finish (Af) temperatures for electro-discharge machining (EDM) instruments. Significant differences in nano-hardness and modulus of elasticity were found between EDM and CM files (P < 0.05). FE-SEM and EDS analyses confirmed that both new EDM and CM files were covered by an oxide layer. Micro-Raman spectroscopy assessed the presence of rutile-TiO2.
Conclusions HyFlex EDM revealed peculiar structural properties, such as increased phase transformation temperatures and hardness. Present results corroborated previous findings and shed light on the enhanced mechanical behaviour of these instruments.
Iris type:
Articolo su rivista
Keywords:
CM wire; Differential scanning calorimetry; Electro-discharge machining; Metallurgical properties; Microstructure; NiTi endodontic instruments; Dentistry (all)
List of contributors:
Iacono, F.; Pirani, C; Generali, Luigi; Bolelli, Giovanni; Sassatelli, Paolo; Lusvarghi, Luca; Gandolfi, M. G.; Giorgini, L.; Prati, C.
Authors of the University:
BOLELLI Giovanni
GENERALI Luigi
LUSVARGHI Luca
Handle:
https://iris.unimore.it/handle/11380/1125727
Published in:
INTERNATIONAL ENDODONTIC JOURNAL
Journal
  • Overview

Overview

URL

www.blackwellpublishing.com/journal.asp?ref=0143-2885
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.2.0