Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills
  1. Research Outputs

Tibolone, oral or transdermal hormone replacement and colour Doppler analysis - A prospective, randomised pilot study

Academic Article
Publication Date:
2004
Short description:
Tibolone, oral or transdermal hormone replacement and colour Doppler analysis - A prospective, randomised pilot study / Battaglia, C., Mancini, F., Persico, N., Penacchioni, P., Regnani, G., Volpe, A., De Aloysio, D.. - In: MATURITAS. - ISSN 0378-5122. - STAMPA. - 48:4(2004), pp. 446-455. [10.1016/j.maturitas.2003.10.008]
abstract:
Objective: To compare the plasma thromboxane, the plasma viscosity and the Doppler flow modifications induced by tibolone and by oral or transdermal continuous combined hormone replacement therapy. Methods: Forty-two post-menopausal patients underwent either on: oral daily treatment with tibolone (2.5 mg) (Group 1; n = 14); or continuous oral administration of 0.625 mg conjugated equine estrogens + medroxyprogesterone 5 mg per day (Group 11; n = 14); or continuous estradiol transdermal supplementation, at a dose of 50 mug per day, + medroxyprogesterone 5 mg per day (Group 111; n = 14). The duration of the study was 6 months and the patients were submitted to transvaginal ultrasonographic evaluation of pelvic organs; Doppler analysis of the uterine, internal carotid and ophthalmic arteries; thromboxane and plasma viscosity assays in basal condition, and at 1, 3 and 6 months from the beginning of the study. Results: Although the endometrial thickness increased significantly, there were no cases in which it exceeded the normal range (less than or equal to5 mm). In all the three groups, the pulsatility index of the uterine, internal carotid and ophthalmic arteries significantly decreased during the therapy showing a reduced impedance since the first month of treatment. Similar variations were observed for the peak systolic blood flow velocity of the internal carotid and ophthalmic arteries. Hormone replacement therapy and tibolone induced a deep, significant and rapid decrease in plasma thromboxane and plasma viscosity levels. Conclusions: Hormone replacement therapy and tibolone seem to have beneficial effects on vascular and hemorrheological parameters. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
Iris type:
Articolo su rivista
Keywords:
Doppler; HRT; menopause; ultrasonography; tibolone
List of contributors:
Battaglia, C; Mancini, F; Persico, N; Penacchioni, P; Regnani, G; Volpe, Annibale; De Aloysio, D.
Handle:
https://iris.unimore.it/handle/11380/4222
Published in:
MATURITAS
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.1.0