Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills
  1. Research Outputs

A randomized multicenter trial comparing the XIENCE everolimus eluting stent with the CYPHER sirolimus eluting stent in the treatment of female patients with de novo coronary artery lesions: The SPIRIT WOMEN study

Academic Article
Publication Date:
2017
Short description:
A randomized multicenter trial comparing the XIENCE everolimus eluting stent with the CYPHER sirolimus eluting stent in the treatment of female patients with de novo coronary artery lesions: The SPIRIT WOMEN study / Franzone, Anna; Zaugg, Serge; Piccolo, Raffaele; Modena, Maria Grazia; Mikhail, Ghada W.; Ferrã©, Josepa Mauri; Strasser, Ruth; Grinfeld, Liliana; Heg, Dik; Jã¼ni, Peter; Windecker, Stephan; Morice, Marie-claude. - In: PLOS ONE. - ISSN 1932-6203. - 12:8(2017), pp. 1-16. [10.1371/journal.pone.0182632]
abstract:
Background: The comparative performance of different drug-eluting stents (DES) among female patients has not been assessed in a randomized manner. Objectives: The SPIRIT Women Clinical Evaluation trial compared the durable polymer everolimus-eluting XIENCE stent (DP-EES) with the durable polymer sirolimus-eluting Cypher stent (DP-SES) in women undergoing percutaneous coronary intervention (PCI). Methods: A total of 455 female patients with stable CAD were randomly assigned to receive DP-EES (n = 304) or DP-SES (n = 151). The powered angiographic outcome of the trial was in-stent late lumen loss (LLL) at 9 months after the index procedure. Secondary angiographic end points included in-segment LLL, in-stent and in-segment binary restenosis and percent diameter stenosis. The primary clinical outcome was a composite of all-cause death, myocardial infarction (MI) or target vessel revascularization (TVR). Results: At 9-month follow-up, in-stent LLL was 0.19±0.38 mm and 0.11±0.37 mm in patients assigned to DP-EES and DP-SES, respectively. The one-sided upper 95% CI of the difference in in-stent LLL between the groups of 0.08 mm was 0.15 and therefore within the pre-specified non-inferiority margin of 0.17 mm (p for non-inferiority = 0.013). However, the test for superiority showed a borderline significant difference in terms of LLL between DP-EES and DP-SES (p for superiority = 0.044). There were no significant differences in binary restenosis (2.0% vs. 0.72%, p = 0.44) and percent diameter stenosis (14.97±12.17 vs. 13.36 ±10.82, p = 0.19). The rate of definite stent thrombosis at 12 months was lower in patients treated with DP-EES (0% vs. 2.0%, p = 0.036). Conclusions: Among women undergoing PCI, DP-EES was associated with a small but probably clinically relevant increase in in-stent LLL at 9 months as compared to DP-SES and with a lower risk of definite stent thrombosis at 12 months. Trial registration: ClinicalTrials.gov NCT01182428.
Iris type:
Articolo su rivista
Keywords:
Aged; Aged, 80 and over; Cardiovascular Agents; Coronary Artery Disease; Everolimus; Humans; Middle Aged; Percutaneous Coronary Intervention; Treatment Outcome; Drug-Eluting Stents; Biochemistry, Genetics and Molecular Biology (all); Agricultural and Biological Sciences (all)
List of contributors:
Franzone, Anna; Zaugg, Serge; Piccolo, Raffaele; Modena, Maria Grazia; Mikhail, Ghada W.; Ferrã©, Josepa Mauri; Strasser, Ruth; Grinfeld, Liliana; Heg, Dik; Jã¼ni, Peter; Windecker, Stephan; Morice, Marie-claude
Authors of the University:
MODENA Maria Grazia
Handle:
https://iris.unimore.it/handle/11380/1148192
Full Text:
https://iris.unimore.it//retrieve/handle/11380/1148192/171227/Modena%202017.pdf
Published in:
PLOS ONE
Journal
  • Overview

Overview

URL

http://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0182632&type=printable
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.4.5.0