Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills
  1. Research Outputs

Optimal positioning of the humeral component in the reverse shoulder prosthesis

Academic Article
Publication Date:
2014
Short description:
Optimal positioning of the humeral component in the reverse shoulder prosthesis / Nalbone, L.; Adelfio, R.; D'Arienzo, Matteo; Ingrassia, T.; Nigrelli, V.; Zabbara, F.; Paladini, P.; Campi, F.; Pellegrini, A.; Porcellini, G.. - In: MUSCULOSKELETAL SURGERY. - ISSN 2035-5106. - 98:2(2014), pp. 135-142. [10.1007/s12306-013-0274-z]
abstract:
Total reverse shoulder arthroplasty is becoming more and more the standard therapeutic practice for glenohumeral arthropathy with massive lesions of the rotator cuff. The biomechanical principle of this prosthesis is represented by the reversion of the normal anatomy of the shoulder joint. This non-anatomical prosthesis leads to a medialization of the rotation centre of the glenohumeral joint and also to a distalization of the humeral head. All that causes a deltoid tension increasing so allowing a larger abduction of the arm. Main complications of the reverse shoulder prosthesis are due to the joint instability, the scapular notching and the wear of the polyethylene insert. Purpose: The main goal of the present work is to study the effect of the positioning of the humeral component on the intrinsic stability of the reverse shoulder prosthesis. In particular, through finite element method simulations, the variation of the stability ratio of the shoulder joint has been calculated for both vertical and horizontal dislocating loads depending on the humeral stem version angle. Moreover, in order to estimate the wear of the polyethylene cup, some analyses have been developed to calculate the pressures on the polyethylene insert. Results: The obtained results demonstrate the dislocation of a shoulder prosthesis and the wear of the polyethylene insert can be prevented or limited by conveniently varying the version angle of the humeral component. © 2013 Istituto Ortopedico Rizzoli.
Iris type:
Articolo su rivista
Keywords:
FEM analyses; Intrinsic stability; Polyethylene wear; Stability ratio; Total reverse shoulder arthroplasty; Arthroplasty, Replacement; Humans; Humerus; Prosthesis Design; Shoulder Joint; Orthopedics and Sports Medicine; Surgery; Medicine (all)
List of contributors:
Nalbone, L.; Adelfio, R.; D'Arienzo, Matteo; Ingrassia, T.; Nigrelli, V.; Zabbara, F.; Paladini, P.; Campi, F.; Pellegrini, A.; Porcellini, G.
Authors of the University:
D'ARIENZO Matteo
PORCELLINI Giuseppe
Handle:
https://iris.unimore.it/handle/11380/1160317
Published in:
MUSCULOSKELETAL SURGERY
Journal
  • Overview

Overview

URL

http://www.springer.com/medicine/orthopedics/journal/12306
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.4.5.0