Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills
  1. Research Outputs

High-Intensity Focused Ultrasound Circular Cyclocoagulation in Glaucoma: A Step Forward for Cyclodestruction?

Academic Article
Publication Date:
2017
Short description:
High-Intensity Focused Ultrasound Circular Cyclocoagulation in Glaucoma: A Step Forward for Cyclodestruction? / Mastropasqua, R; Fasanella, V; Mastropasqua, A; Ciancaglini, M; Agnifili, L. - In: JOURNAL OF OPHTHALMOLOGY. - ISSN 2090-004X. - 2017:(2017), pp. 1-15. [10.1155/2017/7136275]
abstract:
The ciliary body ablation is still considered as a last resort treatment to reduce the intraocular pressure (IOP) in uncontrolled glaucoma. Several ablation techniques have been proposed over the years, all presenting a high rate of complications, nonselectivity for the target organ, and unpredictable dose-effect relationship. These drawbacks limited the application of cyclodestructive procedures almost exclusively to refractory glaucoma. High-intensity focused ultrasound (HIFU), proposed in the early 1980s and later abandoned because of the complexity and side effects of the procedure, was recently reconsidered in a new approach to destroy the ciliary body. Ultrasound circular cyclocoagulation (UC3), by using miniaturized transducers embedded in a dedicated circular-shaped device, permits to selectively treat the ciliary body in a one-step, computer-assisted, and non-operator-dependent procedure. UC3 shows a high level of safety along with a predictable and sustained IOP reduction in patients with refractory glaucoma. Because of this, the indication of UC3 was recently extended also to naïve-to-surgery patients, thus reconsidering the role and timing of ciliary body ablation in the surgical management of glaucoma. This article provides a review of the most used cycloablative techniques with particular attention to UC3, summarizing the current knowledge about this procedure and future possible developments.
Iris type:
Articolo su rivista
List of contributors:
Mastropasqua, R; Fasanella, V; Mastropasqua, A; Ciancaglini, M; Agnifili, L
Handle:
https://iris.unimore.it/handle/11380/1201159
Full Text:
https://iris.unimore.it//retrieve/handle/11380/1201159/262213/j%20ophthalmol%202017.pdf
Published in:
JOURNAL OF OPHTHALMOLOGY
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.1.0