Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills
  1. Research Outputs

Improvement of spatial contrast sensitivity threshold after surgical reduction of intraocular pressure in unilateral high-tension glaucoma

Academic Article
Publication Date:
2005
Short description:
Improvement of spatial contrast sensitivity threshold after surgical reduction of intraocular pressure in unilateral high-tension glaucoma / Gandolfi, Sa; Cimino, L; Sangermani, C; Ungaro, N; Mora, P; Tardini, Mg. - In: INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE. - ISSN 0146-0404. - 46:1(2005), pp. 197-201. [10.1167/iovs.04-0199]
abstract:
PURPOSE. To measure the effect of a surgical reduction of IOP on the spatial contrast sensitivity threshold in eyes showing a considerably increased IOP but no glaucomatous visual field defect, on white-on-white computer-assisted static perimetry. METHODS. Prospective clinical trial, lasting 36 months; 10 consecutive subjects with untreated IOP greater than or equal to 30 mm Hg in one eye and less than or equal to 18 mm Hg in the fellow eye, no evidence of field damage in both eyes, best corrected visual acuity greater than or equal to 20/20 in both eyes, and scheduled for a primary trabeculectomy in the eye showing a high IOP. The spatial contrast sensitivity threshold was measured before surgery and at each follow-up visit. RESULTS. Preoperative spatial contrast sensitivity was worse in those eyes bearing a high IOP relative to the normal fellow eyes (paired samples t-test, P < 0.0005). An improvement of contrast sensitivity threshold, exceeding the 95% confidence limits of the preoperative test-retest variability, was observed at 3, 6, and 12 cyc/deg in each surgical eye at the end of follow-up. No change was observed in the fellow untreated normal eyes. The improvement correlated directly with the amount of decrease in pressure obtained by surgery. CONCLUSIONS. Eyes with no field defects on white-on-white computer-assisted static perimetry, but bearing a IOP &GE; 30 mm Hg, show a decreased spatial contrast sensitivity. A surgically obtained reduction of IOP is paralleled by an improvement of spatial contrast sensitivity.
Iris type:
Articolo su rivista
List of contributors:
Gandolfi, Sa; Cimino, L; Sangermani, C; Ungaro, N; Mora, P; Tardini, Mg
Authors of the University:
CIMINO Luca
Handle:
https://iris.unimore.it/handle/11380/1259023
Published in:
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.4.4.0