Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills
  1. Research Outputs

Glutaraldehyde-based desensitizers’ influence on bonding performances and dentin enzymatic activity of universal adhesives

Academic Article
Publication Date:
2023
Short description:
Glutaraldehyde-based desensitizers’ influence on bonding performances and dentin enzymatic activity of universal adhesives / Mancuso, E.; Durso, D.; Mazzitelli, C.; Maravic, T.; Josic, U.; D'Alessandro, C.; Generali, L.; Checchi, V.; Breschi, L.; Mazzoni, A.. - In: JOURNAL OF DENTISTRY. - ISSN 0300-5712. - 136:(2023), pp. 1-10. [10.1016/j.jdent.2023.104643]
abstract:
Objectives: To evaluate the influence of two glutaraldehyde-based desensitizers (L: GLUMA Desensitizer, Heraeus Kulzer and G: GLUMA Desensitizer PowerGel) prior to the adhesive procedures on microtensile bond strength (µTBS) to dentin and endogenous enzymatic activity. Methods: Noncarious human third molars (N = 48) were cut to expose middle coronal dentin. Six experimental groups were formed according to the dentin pre-treatment (L or G) and the universal adhesives (IBU - iBond universal, Kulzer or AU - Adhese Universal, Ivoclar Vivadent) used in the self-etch mode (n = 8): 1) L/IBU; 2) G/IBU; 3) IBU; 4) L/AU; 5) G/AU; 6) AU. Specimens were cut into sticks and stressed until failure after 24 h (T0) or 1 yr of aging (T12). Additional 4 teeth were used for in situ zymography evaluation and data were statistically analyzed (α = 0.05). Results: Dentin pre-treatment, adhesive and aging statistically influenced bond strength and enzymatic activity (P<0.001). AU demonstrated higher bond strength values than IBU (P<0.001). The L resulted in higher bond strength compared to the G and control groups (P<0.001). aging statistically influenced bonding performance, especially when no dentin pre-treatment was performed (P<0.001). In situ zymography revealed that at baseline the control groups exhibited lower interfacial fluorescence compared to the experimental groups, irrespective of the adhesive used (P<0,001). However, after 1 yr of artificial storage, no differences were found among the groups (P>0.05). Conclusions: : Glutharldeadeyde-based products increased bond strength and determined a stabilization of the adhesive interface over time apparently not related to the MMPs inhibition. Clinical Significance: The results of this in vitro study suggest that the application of glutaraldehyde-based desensitizers prior to the adhesive procedures when associated with universal adhesives could result in increased bond strength and stabilization of the adhesive interface over time.
Iris type:
Articolo su rivista
Keywords:
Dentin; Desensitizers; Glutaraldehyde; Mmp inhibition; Universal adhesive; Zymography
List of contributors:
Mancuso, E.; Durso, D.; Mazzitelli, C.; Maravic, T.; Josic, U.; D'Alessandro, C.; Generali, L.; Checchi, V.; Breschi, L.; Mazzoni, A.
Authors of the University:
CHECCHI VITTORIO
GENERALI Luigi
Handle:
https://iris.unimore.it/handle/11380/1332986
Full Text:
https://iris.unimore.it//retrieve/handle/11380/1332986/637764/1-s2.0-S0300571223002294-main.pdf
Published in:
JOURNAL OF DENTISTRY
Journal
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.4.5.0