Evaluation of fusion beat detection with a new ventricular automatic capture algorithm in ICDs.

Articolo
Data di Pubblicazione:
2005
Citazione:
Evaluation of fusion beat detection with a new ventricular automatic capture algorithm in ICDs / Boriani, Giuseppe; Biffi, M; Schwarz, T; Dong, Y; Koenig, A; Temporin, S; Meyer, S; Sperzel, J.. - In: PACING AND CLINICAL ELECTROPHYSIOLOGY. - ISSN 0147-8389. - 28:1(2005), pp. s263-s266. [10.1111/j.1540-8159.2005.00027.x]
Abstract:
This study evaluated a newly developed automatic capture verification scheme for implantable cardioverter defibrillators (ICDs) regarding discrimination of capture, fusion, and noncapture beats, with an emphasis on fusion detection. The algorithm uses evoked response detection based on a sensing vector from right ventricular shocking coil to Can. Patients undergoing ICD implant or replacement were enrolled in this study. An external system was used for pacing and data acquisition. To provoke ventricular fusion beats, VVI patients were paced close to the rate of their intrinsic rhythm and DDD patients were paced close at their intrinsic PR interval. Surface ECG and wideband filtered intracardiac electrograms were recorded for off-line analysis. Each paced beat was independently classified visually by surface ECG and by the automatic detection algorithm. The algorithm performance was then evaluated by comparing the classification results. Twenty-seven patients (22 males, 5 females; 63.8 +/- 12.5 years) were analyzed. Device and lead demographics were: 18 DDD/9 VVI; 16 dedicated bipolar, 11 integrated bipolar leads; 18 acute, 9 chronic (3.7 +/- 2.0 years) leads. In total, 2064 beats were analyzed, including 1,477 fusion beats and 587 capture beats. Fusion detection sensitivity and specificity were 99.5% and 99.0%, respectively. Seven true-fusion beats (0.5%) were classified as capture and 6 capture beats (1.0%) were identified as fusions. Capture or fusion beats were never detected as non-capture beats. It is concluded that the algorithm was effective in detecting fusion beats. It could potentially be used in ICD applications that need accurate fusion detection.
Tipologia CRIS:
Articolo su rivista
Keywords:
Automatic capture; Fusion beats; Implantable cardioverter defibrillator;
Elenco autori:
Boriani, Giuseppe; Biffi, M; Schwarz, T; Dong, Y; Koenig, A; Temporin, S; Meyer, S; Sperzel, J.
Autori di Ateneo:
BORIANI Giuseppe
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1080516
Pubblicato in:
PACING AND CLINICAL ELECTROPHYSIOLOGY
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.4.5.0