Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Analysis of uniformity of as prepared and irradiated SI GaAs radiation detectors

Articolo
Data di Pubblicazione:
1998
Citazione:
Analysis of uniformity of as prepared and irradiated SI GaAs radiation detectors / Nava, F., P., V., C., C., G., A., C., M., P., P., E., V.. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - 45:(1998), pp. 609-616. [10.1109/23.682458]
Abstract:
SI (semi-insulating) LEC (Liquid Encapsulated Czochralsky) GaAs (gallium arsenide) Schottky barrier detectors have been irradiated with high energy protons (24 GeV/c, fluence up to 16.45x10(13) p/cm2). The detectors have been characterised in terms of I/V curves, charge collection efficiency (cce) for incident 5.48 MeV alpha-, 2 MeV proton and minimum ionizing beta-particles and of cce maps by microprobe technique IBIC (Ion Beam Induced Charge). At the highest fluence a significant degradation of the electron and hole collection efficiencies and a remarkable improvement of the FWHM energy resolution have been measured with alpha- and proton particles. Furthermore the reduction in the cce is greater than the one measured with beta-particles and the energy resolution worsens with increasing the applied bias, V-a, above the voltage V-d necessary to extend the electric field all the way to the ohmic contact. On the contrary, in the unirradiated detectors the charge collection efficiencies with alpha-, beta- and proton particles are quite similar and the energy resolution improves with increasing V-a > V-d. IBIC spectra and IBIC space maps obtained by scanning a focused (8 mu m(2)) 2 MeV proton microbeam on front (Schottky) and back (ohmic) contacts, support the observed electric field dependence of the energy resolution both in unirradiated and most irradiated detectors. The results obtained let us explain the effect of the electric field strength and the plasma on the collection of the charge carriers and the FWHM energy resolution.
Tipologia CRIS:
Articolo su rivista
Elenco autori:
Nava, Filippo; P., Vanni; C., Canali; G., Apostolo; C., Manfredotti; P., Polesello; E., Vittone
Autori di Ateneo:
NAVA Filippo
Link alla scheda completa:
https://iris.unimore.it/handle/11380/307508
Pubblicato in:
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.2.0