Disposable Fluorescence Optical pH Sensor for Near Neutral Solutions

Articolo
Data di Pubblicazione:
2013
Citazione:
Disposable Fluorescence Optical pH Sensor for Near Neutral Solutions / Luca, Ferrari; Rovati, Luigi; Fabbri, Paola; Pilati, Francesco. - In: SENSORS. - ISSN 1424-8220. - STAMPA. - 13:1(2013), pp. 484-499. [10.3390/s130100484]
Abstract:
The design, development and performance evaluation of a fluorescence-based pH sensor for on-line measurements is presented. The pKa of the sensing element has been calculated to be 7.9, thus the sensor is suitable for measurement of near neutral solutions. The sensor consists of a low-cost disposable polymer sensing probe, in contact with the solution under test, interrogated by an optoelectronic transduction system. The pH sensitive dye is based on fluorescein O-methacrylate, which has been covalently linked to a hydrogel matrix, realized through the use of HEMA (2-hydroxyethyl methacrylate), HDDA (1,6-hexanediol diacrylate) and PEGDA (polyethylene glycol diacrylate). The optical interrogation setup, together with the electronics, has been developed to acquire and process the fluorescence signal. The sensor works over a pH range between 6.5 and 9.0. In the range between 7.0 and 8.0, the sensor shows a linear behavior with a maximum linearity error of 5%. Thanks to the good performance of the sensing element and transduction system, the short term drift of the reading (measured over 40 min) is lower than 0.15%. The measuring system also exhibits good performance in terms of response time and reproducibility.
Tipologia CRIS:
Articolo su rivista
Keywords:
optical sensors.; Biosensors; pH sensors; fluorescence sensor; optical mesurements; hydrogels; polymer matrix
Elenco autori:
Luca, Ferrari; Rovati, Luigi; Fabbri, Paola; Pilati, Francesco
Autori di Ateneo:
ROVATI Luigi
Link alla scheda completa:
https://iris.unimore.it/handle/11380/902489
Link al Full Text:
https://iris.unimore.it//retrieve/handle/11380/902489/240642/sensors-13-00484.pdf
Pubblicato in:
SENSORS