Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Cardiac resynchronization therapy: a comparison among left ventricular bipolar, quadripolar and active fixation leads

Articolo
Data di Pubblicazione:
2018
Citazione:
Cardiac resynchronization therapy: a comparison among left ventricular bipolar, quadripolar and active fixation leads / Ziacchi, M.; Diemberger, I.; Corzani, A.; Martignani, C.; Mazzotti, A.; Massaro, G.; Valzania, C.; Rapezzi, C.; Boriani, G.; Biffi, M.. - In: SCIENTIFIC REPORTS. - ISSN 2045-2322. - 8:1(2018), pp. 1-8. [10.1038/s41598-018-31692-z]
Abstract:
We evaluated the performance of 3 different left ventricular leads (LV) for resynchronization therapy: bipolar (BL), quadripolar (QL) and active fixation leads (AFL). We enrolled 290 consecutive CRTD candidates implanted with BL (n = 136) or QL (n = 97) or AFL (n = 57). Over a minimum 10 months follow-up, we assessed: (a) composite technical endpoint (TE) (phrenic nerve stimulation at 8 V@0.4 ms, safety margin between myocardial and phrenic threshold <2V, LV dislodgement and failure to achieve the target pacing site), (b) composite clinical endpoint (CE) (death, hospitalization for heart failure, heart transplantation, lead extraction for infection), (c) reverse remodeling (RR) (reduction of end systolic volume >15%). Baseline characteristics of the 3 groups were similar. At follow-up the incidence of TE was 36.3%, 14.3% and 19.9% in BL, AFL and QL, respectively (p < 0.01). Moreover, the incidence of RR was 56%, 64% and 68% in BL, AFL and QL respectively (p = 0.02). There were no significant differences in CE (p = 0.380). On a multivariable analysis, “non-BL leads” was the single predictor of an improved clinical outcome. QL and AFL are superior to conventional BL by enhancing pacing of the target site: AFL through prevention of lead dislodgement while QL through improved management of phrenic nerve stimulation.
Tipologia CRIS:
Articolo su rivista
Keywords:
Multidisciplinary
Elenco autori:
Ziacchi, M.; Diemberger, I.; Corzani, A.; Martignani, C.; Mazzotti, A.; Massaro, G.; Valzania, C.; Rapezzi, C.; Boriani, G.; Biffi, M.
Autori di Ateneo:
BORIANI Giuseppe
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1167957
Link al Full Text:
https://iris.unimore.it//retrieve/handle/11380/1167957/247005/s41598-018-31692-z.pdf
Pubblicato in:
SCIENTIFIC REPORTS
Journal
  • Dati Generali

Dati Generali

URL

www.nature.com/srep/index.html
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.2.4.0