Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Closed loop stimulation in prevention of vasovagal syncope. Inotropy controlled pacing in vasovagal syncope (INVASY): A multicentre randomized, single blind, controlled study

Articolo
Data di Pubblicazione:
2004
Citazione:
Closed loop stimulation in prevention of vasovagal syncope. Inotropy controlled pacing in vasovagal syncope (INVASY): A multicentre randomized, single blind, controlled study / Occhetta, Eraldo; Bortnik, Miriam; Audoglio, Roberto; Vassanelli, Corrado; Roncarolo, Pierluigi; Chiodi, Leandro; Marcolongo, Marco; Torta, Davide; Zanetta, Marco; Boriani, Giuseppe; Pirisi, Raimondo; Mazza, Antonio; Marconi, Paolo; Igidbashian, Diran; Romano, Salvatore; Manfredini, Ruggero; Tondo, Claudio; Arlotti, Massimo; Chimienti, Marcello; Zamparelli, Luigi; Cioffi, Luciano; Carboni, Angelo; Bongiorni, Maria Grazia; Polimeni, Rocco; Sermasi, Sergio; Del Giudice, Giovanni; Croce, Adriano; Batista Tola, Giovanni; Terrosu, Pierfranco; Bellotti, Paolo; Gazzarata, Massimo; Libero, Luigi; Jorfida, Marcella; Bensoni, Mauro; Barbieri, Daniela; Lombroso, Sergio; Galati, Antonio; Salerno, Jorge; Caico, Salvatore; Bianchi, Enzo Maria; Glenzer, Renato; Zolezzi, Francesco; Negro, Roberto; Sassara, Massimo; De Luca, Fernando. - In: EUROPACE. - ISSN 1099-5129. - 6:6(2004), pp. 538-547. [10.1016/j.eupc.2004.08.009]
Abstract:
Objectives: To determine whether dual-chamber rate-adaptive Closed Loop Stimulation (CLS) could prevent recurrence of Vasovagal Syncope (VVS). Background: During VVS, an increase in myocardial contractility associated with a reduction of ventricular filling produces an increase in baroreceptor afferent flow and a consequent decrease in the heart rate. The CLS algorithm is a form of rate-adaptive pacing, which responds to myocardial contraction dynamics, by measuring variations in right ventricular intracardiac impedance: during an incipient VVS it could increase paced heart rate and avoid bradycardia, arterial hypotension and syncope. Methods: Fifty patients (27 males, mean age 59 ± 18 year) with severe and recurrent vasovagal syncope and positive Head Up Tilt Test (HUTT) with cardioinhibition, received a CLS pacemaker (INOS2, Biotronik GmbH Co., Germany). The primary end point was recurrence of two VVSs during a minimum of 1 year of follow-up. Randomization between DDD-CLS and DDI mode (40 bpm) pacing was performed only during the first stage of the study (first year): 9/26 randomized to DDI mode (control group) and 17/26 in DDD-CLS mode. All the 24 patients recruited in the second stage of the study (second year) were programmed in DDD-CLS mode. Results: Of the nine patients randomized to the DDI mode, seven had recurrences of syncope during the first year. At the end of the first year the nine patients were reprogrammed to the CLS mode and no syncope occurred after reprogramming. The 41 patients programmed to CLS had a mean follow-up of 19 ± 4 months: none reported VVS, only four (10%) reported occasional presyncope and their quality of life greatly improved. Positive HUTT at the end of the first year failed to predict the clinical response to CLS pacing. Conclusions: The study demonstrates the effectiveness of CLS pacing in preventing cardioinhibitory VVS. A possible placebo effect of pacemaker implantation occurred in 22% of patients. © 2004 The European Society of Cardiology. Published by Elsevier Ltd. All rights reserved.
Tipologia CRIS:
Articolo su rivista
Keywords:
Closed loop stimulation; DDD pacing; Vasovagal syncope; Adult; Aged; Arrhythmias, Cardiac; Electric Stimulation Therapy; Female; Humans; Male; Middle Aged; Recurrence; Single-Blind Method; Syncope, Vasovagal; Tilt-Table Test; Pacemaker, Artificial; Cardiology and Cardiovascular Medicine; Physiology (medical)
Elenco autori:
Occhetta, Eraldo; Bortnik, Miriam; Audoglio, Roberto; Vassanelli, Corrado; Roncarolo, Pierluigi; Chiodi, Leandro; Marcolongo, Marco; Torta, Davide; Zanetta, Marco; Boriani, Giuseppe; Pirisi, Raimondo; Mazza, Antonio; Marconi, Paolo; Igidbashian, Diran; Romano, Salvatore; Manfredini, Ruggero; Tondo, Claudio; Arlotti, Massimo; Chimienti, Marcello; Zamparelli, Luigi; Cioffi, Luciano; Carboni, Angelo; Bongiorni, Maria Grazia; Polimeni, Rocco; Sermasi, Sergio; Del Giudice, Giovanni; Croce, Adriano; Batista Tola, Giovanni; Terrosu, Pierfranco; Bellotti, Paolo; Gazzarata, Massimo; Libero, Luigi; Jorfida, Marcella; Bensoni, Mauro; Barbieri, Daniela; Lombroso, Sergio; Galati, Antonio; Salerno, Jorge; Caico, Salvatore; Bianchi, Enzo Maria; Glenzer, Renato; Zolezzi, Francesco; Negro, Roberto; Sassara, Massimo; De Luca, Fernando
Autori di Ateneo:
BORIANI Giuseppe
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1168395
Pubblicato in:
EUROPACE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0