Monocytes-based in vitro assay for a preliminary biocompatibility assessment of blood-contacting devices

Articolo
Data di Pubblicazione:
2019
Citazione:
Monocytes-based in vitro assay for a preliminary biocompatibility assessment of blood-contacting devices / Gemelli, C.; Grande, A.; Ferrari, S.; Tomasi, A.; Cuoghi, A.. - In: EUROPEAN JOURNAL OF INFLAMMATION. - ISSN 1721-727X. - 17:(2019), pp. 205873921882047-205873921882047. [10.1177/2058739218820479]
Abstract:
The biological evaluation of biomaterials is currently defined by the ISO-10993 norm in which parts four and five are dedicated to emo-compatibility and cell toxicity, respectively. Our study will provide a novel in vitro experimental approach for the biocompatibility assessment of biomaterials or medical devices using human primary monocytes as cellular model. In these new settings, human monocytes are exposed to a medium containing the extractable compounds derived from materials or devices; subsequently, cell toxicity and pro-inflammatory effects are analysed through MTT assay, flow cytometry and enzyme-linked immunosorbent assay (ELISA) methodologies. These experimental procedures offer the advantage to use a human and primary cell context belonging to the immune system, in order to accurately predict the nature of blood/device interaction occurring during a clinical application. To validate the reliability of this method, we also reported a comparative study between two different membranes showing a different level of biocompatibility. On the bases of these data, it is possible to state that this new experimental model represents a good approach to investigate the effects induced by a biomaterial on cell death and inflammation using human, primary monocytes.
Tipologia CRIS:
Articolo su rivista
Keywords:
biocompatibility; biomaterials; blood-contacting devices; cell toxicity; extractable compound; inflammation; medical devices; monocytes
Elenco autori:
Gemelli, C.; Grande, A.; Ferrari, S.; Tomasi, A.; Cuoghi, A.
Autori di Ateneo:
FERRARI Sergio
GRANDE Alexis
TOMASI Aldo
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1200291
Link al Full Text:
https://iris.unimore.it//retrieve/handle/11380/1200291/497463/2058739218820479.pdf
Pubblicato in:
EUROPEAN JOURNAL OF INFLAMMATION
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0