Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Nocturnal Sleep Dynamics Identify Narcolepsy Type 1

Articolo
Data di Pubblicazione:
2015
Citazione:
Nocturnal Sleep Dynamics Identify Narcolepsy Type 1 / Pizza, F., Vandi, S., Iloti, M., Franceschini, C., Liguori, R., Mignot, E., Plazzi, G.. - In: SLEEP. - ISSN 0161-8105. - 38:8(2015), pp. 1277-1284. [10.5665/sleep.4908]
Abstract:
To evaluate the reliability of nocturnal sleep dynamics in the differential diagnosis of central disorders of hypersomnolence. Cross-sectional. Sleep laboratory.One hundred seventy-five patients with hypocretin-deficient narcolepsy type 1 (NT1, n = 79), narcolepsy type 2 (NT2, n = 22), idiopathic hypersomnia (IH, n = 22), and "subjective" hypersomnolence (sHS, n = 52).None.Polysomnographic (PSG) work-up included 48 h of continuous PSG recording. From nocturnal PSG conventional sleep macrostructure, occurrence of sleep onset rapid eye movement period (SOREMP), sleep stages distribution, and sleep stage transitions were calculated. Patient groups were compared, and receiver operating characteristic (ROC) curve analysis was used to test the diagnostic utility of nocturnal PSG data to identify NT1.Sleep macrostructure was substantially stable in the 2 nights of each diagnostic group. NT1 and NT2 patients had lower latency to rapid eye movement (REM) sleep, and NT1 patients showed the highest number of awakenings, sleep stage transitions, and more time spent in N1 sleep, as well as most SOREMPs at daytime PSG and at Multiple Sleep Latency Tests (MSLTs) than all other groups. ROC curve analysis showed that nocturnal SOREMP (area under the curve of 0.724 ± 0.041, P < 0.0001), percent of total sleep time spent in N1 (0.896 ± 0.023, P < 0.0001), and the wakefulness-sleep transition index (0.796 ± 0.034, P < 0.0001) had a good sensitivity and specificity profile to identify NT1 sleep, especially when used in combination (0.903 ± 0.023, P < 0.0001), similarly to SOREMP number at continuous daytime PSG (0.899 ± 0.026, P < 0.0001) and at MSLT (0.956 ± 0.015, P < 0.0001).Sleep macrostructure (i.e. SOREMP, N1 timing) including stage transitions reliably identifies NT1 among central disorders of hypersomnolence.
Tipologia CRIS:
Articolo su rivista
Keywords:
sleep; hypersomnia
Elenco autori:
Pizza, F.; Vandi, S.; Iloti, M.; Franceschini, C.; Liguori, R.; Mignot, E.; Plazzi, G.
Autori di Ateneo:
PLAZZI Giuseppe
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1205878
Pubblicato in:
SLEEP
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.2.0