Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Hygroscopic condenser humidifiers in chronically tracheostomized patients who breathe spontaneously.

Articolo
Data di Pubblicazione:
1994
Citazione:
Hygroscopic condenser humidifiers in chronically tracheostomized patients who breathe spontaneously / M., V., Clini, E., K., F., S., S., S., M., A., Q., N., A.. - In: EUROPEAN RESPIRATORY JOURNAL. - ISSN 0903-1936. - ELETTRONICO. - 7:(1994), pp. 2026-2032.
Abstract:
The aim of this study was to test the usefulness of hygroscopic condenser humidifiers on secretion and on inspired gas temperature in tracheostomized patients. Forty spontaneously breathing chronically tracheostomized patients were divided into two groups: Group 1 received a hygroscopic condenser humidifier connected to the tracheostomy, 24 h daily for 10 days; Group 2, without any protection system, was chosen as the control group. The daily number of tracheal suctions, quantity of aspirate and thickness and colouring of secretions was evaluated. At baseline, and at days 5 and 10, patients were submitted to blood gas analysis, respiratory function tests and sputum analysis. The temperature of gases breathed was measured at rest and during a hyperventilation test, with and without the hygroscopic condenser humidifier. Statistically significant differences were found in thickness and colouring of secretions between the two groups during the period of 10 days. Group 2 showed a significantly greater trend in number of bacteria than Group 1. The group with the hygroscopic condenser humidifier showed respiratory function improvement over time for forced expiratory volume in one second (FEV1) and tidal volume (VT), maximal inspiratory pressure (MIP), and maximal voluntary ventilation (MVV) in comparison to the control group, who did not. Significant differences in the temperature between rest and hyperventilation, with and without a hygroscopic condenser humidifier were also found. In conclusion, a hygroscopic condenser humidifier may be useful in chronically tracheostomized patients who breathe spontaneously, improving viscosity and colouring of secretions, preventing further bacterial colonization, heating inspiratory flow, and helping to improve the functional outcome.
Tipologia CRIS:
Articolo su rivista
Keywords:
tracheostomy; humidification; hygroscopic condenser humidifier
Elenco autori:
M., Vitacca; Clini, Enrico; K., Foglio; S., Scalvini; S., Marangoni; A., Quadri; N., Ambrosino
Autori di Ateneo:
CLINI Enrico
Link alla scheda completa:
https://iris.unimore.it/handle/11380/593128
Pubblicato in:
EUROPEAN RESPIRATORY JOURNAL
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.2.0