Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Frequency reallocation based on cochlear place frequencies in cochlear implants: a pilot study

Articolo
Data di Pubblicazione:
2022
Citazione:
Frequency reallocation based on cochlear place frequencies in cochlear implants: a pilot study / Di Maro, F.; Carner, M.; Sacchetto, A.; Soloperto, D.; Marchioni, D.. - In: EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY. - ISSN 0937-4477. - 279:10(2022), pp. 4719-4725. [10.1007/s00405-021-07245-y]
Abstract:
Purpose: The aim of this study is to evaluate speech perception outcomes after a frequency reallocation performed through the creation of an anatomically based map obtained with Otoplan®, a tablet-based software that allows the cochlear duct length to be calculated starting from CT images. Methods: Ten postlingually deafened patients who underwent cochlear implantation with MED-EL company devices from 2015 to 2019 in the Tertiary referral center University Hospital of Verona have been included in a retrospective study. The postoperative CT scans were evaluated with Otoplan®; the position of the intracochlear electrodes was obtained, an anatomical mapping was carried out and then it was submitted to the patients. All patients underwent pure tonal and speech audiometry before and after the reallocation and the audiological results were processed considering the Speech Recognition Threshold (SRT), the Speech Awareness Threshold (SAT) and the Pure Tone Average (PTA). The differences in the PTA, SAT and SRT values before and after the reallocation were determined. The results were statistically processed using the software Stata with a significance value of α < 0.05. Results: The mean values of SRT (61.25 dB versus 51.25 dB) and SAT (49 dB versus 41 dB) were significantly lower (p: 0.02 and p: 0.04, respectively) after the reallocation. No significant difference was found between PTA values (41.5 dB versus 39.25 dB; p: 0.18). Conclusions: Our preliminary results demonstrate better speech discrimination and rapid adaptation in implanted postlingually deaf patients after anatomic mapping and subsequent frequency reallocation.
Tipologia CRIS:
Articolo su rivista
Keywords:
Anatomy-based fitting; Cochlear implant; Frequency reallocation; Frequency-to-place mismatch
Elenco autori:
Di Maro, F.; Carner, M.; Sacchetto, A.; Soloperto, D.; Marchioni, D.
Autori di Ateneo:
MARCHIONI Daniele
SOLOPERTO DAVIDE
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1279557
Link al Full Text:
https://iris.unimore.it//retrieve/handle/11380/1279557/424834/Maro2022_Article_FrequencyReallocationBasedOnCo.pdf
Pubblicato in:
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0