Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

A modified & epsilon;-NTU analytical model for the investigation of counter-flow Maisotsenko-based cooling systems

Articolo
Data di Pubblicazione:
2023
Citazione:
A modified & epsilon;-NTU analytical model for the investigation of counter-flow Maisotsenko-based cooling systems / Muscio, A; Cossu, M; Morselli, N; Puglia, M; Pedrazzi, S; Allesina, G. - In: APPLIED THERMAL ENGINEERING. - ISSN 1359-4311. - 231:(2023), pp. 1-14. [10.1016/j.applthermaleng.2023.120944]
Abstract:
In this work the e-NTU method has been adapted for the application of a countercurrent evaporative heat exchanger featuring a complex heat transfer surface. The study highlights some challenges related to extending analytical models that were validated on simple geometries and proposes the calibration of the e-NTU method by experimentally measuring the overall heat transfer coefficient (UA) of the heat exchanger. Through a laboratory prototype of the M-cycle, two different operating conditions were investigated (mild and hot-dry climates) which reported almost constant UA values of 14.8 W/K and 16.1 W/K respectively. The obtained results from the model prediction were compared with the experimental data obtaining average errors on the outlet temperatures and on the cooling capacity lower than 1.5% in the case of simulation of hot and dry climate. The positive results allowed to extend the calculation to operating conditions not tested experimentally, highlighting how it is necessary to have NTU over 2-2.5, while the recirculation rate must be kept below 0.4 to make efficient use of the water. The aim is to support the implementation of the technology in full-scale applications, where the M-cycle is used alone or to complement a vapor compression system.
Tipologia CRIS:
Articolo su rivista
Keywords:
Maisotsenko cycle; Indirect evaporative cooling; & epsilon;-NTU method; Dew point temperature
Elenco autori:
Muscio, A; Cossu, M; Morselli, N; Puglia, M; Pedrazzi, S; Allesina, G
Autori di Ateneo:
ALLESINA GIULIO
MORSELLI NICOLO'
MUSCIO Alberto
PEDRAZZI Simone
PUGLIA MARCO
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1314929
Link al Full Text:
https://iris.unimore.it//retrieve/handle/11380/1314929/757598/1-s2.0-S1359431123009730-main.pdf
Pubblicato in:
APPLIED THERMAL ENGINEERING
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0