Feasibility of Shoulder Kinematics Assessment Using Magnetic Inertial Measurement Units in Hemiplegic Patients after Stroke: A Pilot Study

Articolo
Data di Pubblicazione:
2023
Citazione:
Feasibility of Shoulder Kinematics Assessment Using Magnetic Inertial Measurement Units in Hemiplegic Patients after Stroke: A Pilot Study / Longhi, M.; Donati, D.; Mantovani, M.; Casarotti, S.; Calbucci, L.; Puglisi, G.; Platano, D.; Benedetti, M. G.. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 13:21(2023), pp. N/A-N/A. [10.3390/app132111900]
Abstract:
Scapulothoracic movements are altered after stroke, with resulting shoulder dysfunction. The scapulohumeral rhythm (SHR) is complex and poorly studied. Magnetic inertial measurement units (MIMUs) allow a rapid and accurate analysis of shoulder kinematics. MIMUs were used to assess the SHR during active shoulder flexion and abduction of over 60°. SHR values obtained from the hemiplegic shoulders of stroke patients (n = 7) were compared with those from healthy controls (n = 25) and correlated with clinical–functional measurements. The impairment of paretic arms was assessed using the Fugl-Meyer Assessment (FMA). We found that in paretic shoulders, the scapular tilt was significantly lower at maximal arm flexion and at 60° and 90° of arm abduction. On the paretic side, the SHR was also consistently lower for all measured arm movements. The FMA was correlated with the scapular anterior–posterior tilt at 60° and 90° of shoulder abduction (Rho = 0.847, p = 0.016, and Rho = 0.757, p = 0.049, respectively). This pilot study demonstrates the feasibility of MIMUs in assessing SHR in stroke patients and confirms previous findings on scapular dysfunction in stroke patients.
Tipologia CRIS:
Articolo su rivista
Keywords:
hemiplegia; inertial sensor; kinematics; scapula; shoulder; stroke
Elenco autori:
Longhi, M.; Donati, D.; Mantovani, M.; Casarotti, S.; Calbucci, L.; Puglisi, G.; Platano, D.; Benedetti, M. G.
Autori di Ateneo:
DONATI DANILO
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1348081
Link al Full Text:
https://iris.unimore.it//retrieve/handle/11380/1348081/747345/applsci-13-11900.pdf
Pubblicato in:
APPLIED SCIENCES
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0