Minimizing artifact-induced false-alarms for seizure detection in wearable EEG devices with gradient-boosted tree classifiers

Articolo
Data di Pubblicazione:
2024
Citazione:
Minimizing artifact-induced false-alarms for seizure detection in wearable EEG devices with gradient-boosted tree classifiers / Ingolfsson, T. M.; Benatti, S.; Wang, X.; Bernini, A.; Ducouret, P.; Ryvlin, P.; Beniczky, S.; Benini, L.; Cossettini, A.. - In: SCIENTIFIC REPORTS. - ISSN 2045-2322. - 14:1(2024), pp. 10-20. [10.1038/s41598-024-52551-0]
Abstract:
Electroencephalography (EEG) is widely used to monitor epileptic seizures, and standard clinical practice consists of monitoring patients in dedicated epilepsy monitoring units via video surveillance and cumbersome EEG caps. Such a setting is not compatible with long-term tracking under typical living conditions, thereby motivating the development of unobtrusive wearable solutions. However, wearable EEG devices present the challenges of fewer channels, restricted computational capabilities, and lower signal-to-noise ratio. Moreover, artifacts presenting morphological similarities to seizures act as major noise sources and can be misinterpreted as seizures. This paper presents a combined seizure and artifacts detection framework targeting wearable EEG devices based on Gradient Boosted Trees. The seizure detector achieves nearly zero false alarms with average sensitivity values of 65.27% for 182 seizures from the CHB-MIT dataset and 57.26% for 25 seizures from the private dataset with no preliminary artifact detection or removal. The artifact detector achieves a state-of-the-art accuracy of 93.95% (on the TUH-EEG Artifact Corpus dataset). Integrating artifact and seizure detection significantly reduces false alarms—up to 96% compared to standalone seizure detection. Optimized for a Parallel Ultra-Low Power platform, these algorithms enable extended monitoring with a battery lifespan reaching 300 h. These findings highlight the benefits of integrating artifact detection in wearable epilepsy monitoring devices to limit the number of false positives.
Tipologia CRIS:
Articolo su rivista
Elenco autori:
Ingolfsson, T. M.; Benatti, S.; Wang, X.; Bernini, A.; Ducouret, P.; Ryvlin, P.; Beniczky, S.; Benini, L.; Cossettini, A.
Autori di Ateneo:
BENATTI SIMONE
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1355852
Link al Full Text:
https://iris.unimore.it//retrieve/handle/11380/1355852/696434/s41598-024-52551-0.pdf
Pubblicato in:
SCIENTIFIC REPORTS
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.2.4.0