Full-scale experiments of fire suppression in high-hazard storages: A temperature-based analysis of water-mist systems

Articolo
Data di Pubblicazione:
2012
Citazione:
Full-scale experiments of fire suppression in high-hazard storages: A temperature-based analysis of water-mist systems / Santangelo, Paolo Emilio; Tartarini, Paolo. - In: APPLIED THERMAL ENGINEERING. - ISSN 1359-4311. - STAMPA. - 45-46:(2012), pp. 99-107. [10.1016/j.applthermaleng.2012.04.011]
Abstract:
Water-mist systems have become quite popular over the last two decades as an innovative technology in fire protection. Moreover, insertion of additives to the flow may be applied to provide additionalimprovements in terms of suppression effectiveness and temperature control. The present work consists of an experimental approach within a real-scale facility, which has been aimed at challenging water mistagainst severe fire scenarios. Among them, a high-rise storage has been here explored, being it commonly recognized as strongly hazardous even by technical standards in terms of both nominal fireload and designed physical domain. The system configuration presents high-pressure nozzles at the ceiling; the sole-water flow is compared to water endowed with a commercial additive.The thermal transient within the test chamber has been evaluated during the fire development as the main quantitative parameter; moreover, the fire evolution has been visualized through a post-fireestimation of the damages. Despite the large amount of released smoke and smoldering materials, water mist is shown to be efficient in fire control, if endowed with the chosen additive. On the otherhand, the sole-water flow does not appear suitable for such hazardous conditions under the designed nozzle arrangement.
Tipologia CRIS:
Articolo su rivista
Keywords:
Water mist; Fire suppression; Large scale; Thermal transient; Additives
Elenco autori:
Santangelo, Paolo Emilio; Tartarini, Paolo
Autori di Ateneo:
SANTANGELO Paolo Emilio
TARTARINI Paolo
Link alla scheda completa:
https://iris.unimore.it/handle/11380/742040
Pubblicato in:
APPLIED THERMAL ENGINEERING
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0