Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Meta-analysis of randomized controlled trials evaluating left ventricular vs. biventricular pacing in heart failure: effect on all-cause mortality and hospitalizations.

Articolo
Data di Pubblicazione:
2012
Citazione:
Meta-analysis of randomized controlled trials evaluating left ventricular vs. biventricular pacing in heart failure: effect on all-cause mortality and hospitalizations / Boriani, Giuseppe; Gardini, B; Diemberger, I; Bacchi Reggiani, Ml; Biffi, M; Martignani, C; Ziacchi, M; Valzania, C; Gasparini, M; Padeletti, L; Branzi, A.. - In: EUROPEAN JOURNAL OF HEART FAILURE. - ISSN 1388-9842. - STAMPA. - 14:6(2012), pp. 652-660. [10.1093/eurjhf/hfs040 ]
Abstract:
Aim Randomized controlled trials (RCTs) showed that biventricular (BiV) pacing reduces heart failure (HF) hospitalizations and mortality in patients with New York Heart Association (NYHA) class III-IV HF, left ventricular (LV) dysfunction, and wide QRS. We performed a systematic review and meta-analysis of the RCTs comparing LV-only vs. biventricular (BiV) pacing in candidates for cardiac resynchronization therapy (CRT). METHODS AND RESULTS: The systematic review selected five RCTs (out of 1888 analysed reports) with a cumulative number of 372 patients randomized to BiV pacing and 258 to LV-only pacing. The meta-analysis shows that BiV pacing is not superior to LV-only pacing and that these two pacing modalities do not differ with regard to death or heart transplantation [LV-only vs. BiV pacing odds ratio (OR) 1.24, 95% confidence interval (CI) 0.57-2.70 with the fixed effect model, OR 1.25, 95% CI 0.48-3.24 with the random effect model]. Specific data on hospitalizations were available only in two RCTs with a cumulative number of 127 patients randomized to BiV and 123 to LV-only pacing. The meta-analysis shows that BiV pacing is not superior to LV-only pacing and that these two pacing modalities do not differ with regard to this outcome (LV-only vs. BiV pacing OR 0.86, 95% CI 0.49-1.50 with the fixed effect model, OR 0.86, 95% CI 0.49-1.50 with the random effect model). CONCLUSIONS: Biventricular pacing is not superior to LV-only pacing, and these two pacing modalities appear to achieve similar efficacy in candidates for CRT for moderate to severe HF, in terms of all-cause mortality and hospitalizations during follow-up.
Tipologia CRIS:
Articolo su rivista
Keywords:
CARDIAC RESYNCHRONIZATION THERAPY; Heart failure; Morbidity; Mortality; OUTCOME; Pacing; Prognosis
Elenco autori:
Boriani, Giuseppe; Gardini, B; Diemberger, I; Bacchi Reggiani, Ml; Biffi, M; Martignani, C; Ziacchi, M; Valzania, C; Gasparini, M; Padeletti, L; Branzi, A.
Autori di Ateneo:
BORIANI Giuseppe
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1080320
Pubblicato in:
EUROPEAN JOURNAL OF HEART FAILURE
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.1.0