Impact of extending device longevity on the long-term costs of implantable cardioverter-defibrillator therapy: a modelling study with a 15-year time horizon.

Articolo
Data di Pubblicazione:
2013
Citazione:
Impact of extending device longevity on the long-term costs of implantable cardioverter-defibrillator therapy: a modelling study with a 15-year time horizon / Boriani, Giuseppe; Braunschweig, F; Deharo, Jc; Leyva, F; Lubinski, A; Lazzaro, C.. - In: EUROPACE. - ISSN 1099-5129. - 15:10(2013), pp. 1453-1462. [10.1093/europace/eut133]
Abstract:
AIMS: To determine the long-term costs of extending device longevity in four patient populations requiring a single-chamber implantable cardioverter-defibrillator (ICD) or requiring cardiac resynchronization therapy with defibrillation (CRT-D) device over a 15-year time window.METHODS AND RESULTS: We considered patient populations with an accepted indication for a single-chamber ICD for prevention of sudden cardiac death in the context of preserved (Population A) or impaired (Population B) left ventricular function; or with indication for a CRT-D device in the context of heart failure in New York Heart Association class II (Population C) or III (Population D). Expected patient survival and a cost analysis, including the cost of complications, was undertaken from a hospital perspective. Extended device longevity of 5 vs. 9 years for ICDs (Populations A and B); 4 vs. 7 years for CRT-Ds (Populations C and D) were considered. Over a 15-year time horizon, total, yearly, and per diem savings, per patient, from extending ICD longevity to 9 years were €10 926.91, €728.46, and €1.99 for Population A, and €7661.32, €510.75, and €1.40 for Population B. Total, yearly, and per diem savings from extending CRT-D longevity to 7 years were €13 630.38, €908.69, and €2.49 for Population C, and €10 968.29, €731.22, and €2.00 for Population D. Avoidance of a generator replacement amounted up to 46.6-62.5% of the saving.CONCLUSION: Extending device longevity has an important effect on the long-term cost of device therapy, both for ICD and CRT-D. This has important implications for device choice.
Tipologia CRIS:
Articolo su rivista
Keywords:
IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; COSTS; HEALTH ECONOMICS
Elenco autori:
Boriani, Giuseppe; Braunschweig, F; Deharo, Jc; Leyva, F; Lubinski, A; Lazzaro, C.
Autori di Ateneo:
BORIANI Giuseppe
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1080449
Link al Full Text:
https://iris.unimore.it//retrieve/handle/11380/1080449/470304/eut133.pdf
Pubblicato in:
EUROPACE