Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Corsi
  • Insegnamenti
  • Professioni
  • Persone
  • Pubblicazioni
  • Strutture
  • Terza Missione
  • Attività
  • Competenze
  1. Pubblicazioni

Transvenous internal cardioversion for atrial fibrillation: a randomized study on defibrillation threshold and tolerability of asymmetrical compared with symmetrical shocks

Articolo
Data di Pubblicazione:
1999
Citazione:
Transvenous internal cardioversion for atrial fibrillation: a randomized study on defibrillation threshold and tolerability of asymmetrical compared with symmetrical shocks / Boriani, Giuseppe; Biffi, M; Zannoli, R; Branzi, A; Magnani, B.. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 0167-5273. - 71:1(1999), pp. 63-69. [10.1016/S0167-5273(99)00116-3]
Abstract:
The aim of the study was to compare, according to a randomized cross-over design, two different biphasic waveforms (6.5/2.5 ms and 3.0/3.0 ms phases duration, respectively) for low energy internal atrial cardioversion with regard to energy requirements for cardioversion and shock induced discomfort. Methods: Nineteen patients with chronic persistent atrial fibrillation (AF)(mean duration 16+/-20 months) were submitted to internal atrial cardioversion (shock delivery between catheters in right atrium and coronary sinus, respectively) and were randomly allocated to baseline cardioversion with an asymmetrical biphasic shock (6.5/2.5 ms) or with a symmetrical biphasic shock (3.0/3.0 ms), according to a step up protocol. After baseline cardioversion, a sustained AF was reinduced and the patients crossed to the alternative waveform. The procedure was performed without routine administration of sedatives and shock induced discomfort was monitored by a subjective score (1 to 5). Sedatives or anesthetics were administered at patient's request. Results: The procedure was effective in all the patients and was performed without need for sedatives/anesthetics in 17/19 patients (89%). Leading edge voltage of effective shocks resulted lower for asymmetrical shocks compared to symmetrical shocks (290+/-76 vs. 337+/-104 V, P<0.001) with no statistically significant differences in delivered energy (7.74+/-4.25 vs. 8.65+/-5.94 J). Moreover shock induced discomfort resulted lower for asymmetrical shocks compared to symmetrical (pain score=4.18+/-0.73 vs. 4.59+/-0.62, P<0.02). Shock impedence of effective shocks was 59+/-10 ohms for both waveforms. No significant complications occurred during the procedure and no ventricular arrhythmia was observed after atrial cardioversion. Transient bradycardia requiring support ventricular pacing was observed in one patient. Conclusions: Delivery of biphasic asymmetrical shocks (6.5/2.5 ms) results in lower leading edge voltage of effective shocks and better patients tolerability compared with conventional biphasic symmetrical shocks (3.0/3.0 ms). These findings are of interest both for transvenous internal cardioversion of chronic persistent AF and for implantable atrial defibrillators. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
Tipologia CRIS:
Articolo su rivista
Elenco autori:
Boriani, Giuseppe; Biffi, M; Zannoli, R; Branzi, A; Magnani, B.
Autori di Ateneo:
BORIANI Giuseppe
Link alla scheda completa:
https://iris.unimore.it/handle/11380/1080504
Pubblicato in:
INTERNATIONAL JOURNAL OF CARDIOLOGY
Journal
  • Utilizzo dei cookie

Realizzato con VIVO | Designed by Cineca | 26.5.0.0