Skip to Main Content (Press Enter)

Logo UNIMORE
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills

UNI-FIND
Logo UNIMORE

|

UNI-FIND

unimore.it
  • ×
  • Home
  • Degree programmes
  • Modules
  • Jobs
  • People
  • Research Outputs
  • Academic units
  • Third Mission
  • Projects
  • Skills
  1. Research Outputs

Influence of secondary preparative parameters and aging effects on PLGA particle size distribution: a sedimentation field flow fractionation investigation

Academic Article
Publication Date:
2013
Short description:
Influence of secondary preparative parameters and aging effects on PLGA particle size distribution: a sedimentation field flow fractionation investigation / C., C., Vighi, E., A., D., Leo, E.G.. - In: ANALYTICAL AND BIOANALYTICAL CHEMISTRY. - ISSN 1618-2642. - ELETTRONICO. - 405:2-3(2013), pp. 703-711. [10.1007/s00216-012-6113-5]
abstract:
Poly(lactic-co-glycolic acid) particles in the 200-400-nm size range were formulated through nanoprecipitation and solvent evaporation methods. Different concentrations of the polymer and stabilizer (Pluronic® F 68) were tested in order to identify the best conditions for making poly(lactic-co-glycolic acid) particles of suitable size, stable in time, and to be used as carriers for brain-targeting drugs. The particles with the best characteristics for delivery system design were those formulated by nanoprecipitation with an organic/water phase ratio of 2:30, a polymer concentration of 25 mg/mL, and a surfactant concentration of 0.83 mg/mL; their surface charge was reasonably negative (approximately -27 mV) and the average size of the almost monodisperse population was roughly 250 nm. Particle characterization was obtained through ζ-potential measurements, scanning electron microscope observations, and particle size distribution determinations; the latter achieved by both photon-correlation spectroscopy and sedimentation field flow fractionation. Sedimentation field flow fractionation, which is considered more reliable than photon-correlation spectroscopy in describing the possible particle size distribution modifications, was used to investigate the effects of 3 months of storage at 4 °C had on the lyophilized particles
Iris type:
Articolo su rivista
Keywords:
Nanoparticles, Photon-correlation spectroscopy, Poly(lactic-co-glycolic acid), Sedimentation field flow fractionation, Size analysis
List of contributors:
C., Contado; Vighi, Eleonora; A., Dalpiaz; Leo, Eliana Grazia
Authors of the University:
LEO Eliana Grazia
Handle:
https://iris.unimore.it/handle/11380/812506
Published in:
ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Journal
  • Overview

Overview

URL

http://www.ncbi.nlm.nih.gov/pubmed/22644156
  • Use of cookies

Powered by VIVO | Designed by Cineca | 26.5.2.0